Size
|
5" (127 mm) (L) x 3" (76.2 mm) (W) x 1.25" (31.75 mm) (H)
|
|
Weight
|
8 OZ (.23 kg)
|
|
Thickness range
|
0.008 - 20 inches (.20 mm - 508 mm) depending on material, temperature and transducer selection
|
|
Material Velocity Calibration Range
|
0.0200 - 0.7362 in/uS (0.508 - 18.699 mm/uS)
|
|
Temperature
|
Gage Operating: -4° F to 122° F (-20° C to 50° C) Surface temperature of material: Depending on probe use, from -5° F to 1000° F (-20° C to 537° C)
|
|
Battery life
|
Up to 50 hours (25 hours with backlight on)
|
|
Battery type
|
2 "AA" Alkaline
|
|
Color Display
|
170 X 220 pixels, high resolution TFT color display
|
|
Information displays
|
LOS, min, max, large reading while displaying min at the same time, velocity, zero, calibration, units, freeze, unfreeze, % battery life remaining, gain - low, std, high, echo to echo symbol
|
|
Resolution
|
.001" (.01 mm)
|
|
Auto Probe Setup Parameters
|
Via pick list from a menu to set up gain, v-path and sensitivity
|
|
Delay line zero measurement
|
Auto at power up with listed numeric value. Ideal for correcting delay line wear/curvature and for transducer acoustic drift at elevated temperatures
|
|
Package
|
Custom, splash-proof, high impact plastic with illuminating rubber keypad for go/no-go testing
|
|
Bandwidth
|
0.5-20 MHz (-3dB)
|
|
Units
|
English/Metric/Microseconds
|
|
Gain
|
Low, Standard and High for varying test conditions
|
|
Measurement rate
|
4 or 20 measurements per second
|
|
Differential Mode
|
Displays the difference from the actual thickness measurement and a user entered reference value
|
|
Alarms
|
Minimum/Maximum depth, vibralarm, beeps and display flashes as well as keypad illumination
|
|
Illuminating keypad
|
F1 = Red, F2 = Yellow and F3 = Green for easy,
|
|
Automatic probe wear indicator
|
(Transducer attendant): Automatically informs the operator to replace the transducer (Patent Pending)
|
|
Ergonomics
|
User selectable lefty or rightly display changes via keypad (Patent Pending)
|
|
Backlight
|
Light Emitting Diode (LED), On/Off or Auto On based on valid readings or last key press
|
|
Shut off
|
Auto, time out (user programmable from 5-31 minutes or Never shut off)
|
|
Fast Scan Min/Max mode
|
Displays minimum or maximum thickness value at 20 measurements per second (ideal for high temperature thickness reading and tracking the minimum depth) while also displaying actual thickness.
|
|
Protective Pouch
|
Custom molded pouch with belt clip and wrist strap for either lefty or righty operators
|
|
Carrying case
|
Hard Plastic with high density molded cut out for all accessories
|
|
Freeze mode
|
Freezes display to hold onto last reading (ideal for high temperature applications)
|
|
Hold mode
|
Holds display to retain last thickness reading in reverse video display
|
|
Standard EHC-09 Wave Series includes
|
Ultrasonic thickness gage with 5MHz, 0.375 inch diameter transducer with potted cable, operational manual, cable, couplant and protective pouch
|