Click to enlarge image(s)
|
From Danatronics Corp. USA, world’s smallest ultrasonic thickness gage with high resolution waveform display, The EHC-09 with live Waveform (A-Scan), B-Scan, 50K thickness reading
(5000 waveforms) datalogger with interface program. Auto range centers echoes in the middle of the screen independent of material thickness. The blanking and gain adjustments are ideal for complete waveform adjustment and control. The echo to echo feature can ignore the paint or coating thickness. Unique features include:
Auto Zoom tracking centers echoes in the middle of the screen independent of material thickness. The main bang as well as manual and automatic gain adjustments are ideal for complete waveform adjustment and control. RF, Full Wave, Half Wave + and Half Wave - rectification modes. Typical applications include boiler tubes, pressure vessels, storage tanks, ship hulls, containers, home oil tanks, pipes, steam lines, compressors, shafts, bridge pins, bond inspection.
Software options are field upgradeable.
|
Size
|
5" (127 mm) (L) x 3" (76.2 mm) (W) x 1.25" (31.75 mm) (H)
|
|
Weight
|
8 OZ (.23 kg)
|
|
Thickness range
|
0.008 - 20 inches (.20 mm - 508 mm) depending on material, temperature and transducer selection
|
|
Material Velocity Calibration Range
|
0.0200 - 0.7362 in/uS (0.508 - 18.699 mm/uS)
|
|
Temperature
|
Gage Operating: -4° F to 122° F (-20° C to 50° C) Surface temperature of material: Depending on probe use, from -5° F to 1000° F (-20° C to 537° C)
|
|
Battery life
|
Up to 50 hours (25 hours with backlight on)
|
|
Battery type
|
2 "AA" Alkaline
|
|
Information displays
|
LOS, min, max, large reading while displaying min at the same time, velocity, zero, calibration, units, freeze, unfreeze, % battery life remaining, gain - low, std, high, echo to echo symbol
|
|
Resolution
|
.001" (.01 mm)
|
|
Auto Probe Setup Parameters
|
Via pick list from a menu to set up gain, v-path and sensitivity
|
|
Delay line zero measurement
|
Auto at power up with listed numeric value. Ideal for correcting delay line wear/curvature and for transducer acoustic drift at elevated temperatures
|
|
Bandwidth
|
0.5-20 MHz (-3dB)
|
|
Units
|
English/ Metric/ Microseconds
|
|
Gain
|
Low, Standard and High for varying test conditions
|
|
Measurement rate
|
4 or 20 measurements per second
|
|
Differential Mode
|
Displays the difference from the actual thickness measurement and a user entered reference value
|
|
Alarms
|
Minimum/Maximum depth, vibralarm, beeps and display flashes as well as keypad illumination
|
|
Backlight
|
Light Emitting Diode (LED), On/Off or Auto On based on valid readings or last key press
|
|
Fast Scan Min/Max mode
|
Displays minimum or maximum thickness value at 20 measurements per second (ideal for high temperature thickness reading and tracking the minimum depth) while also displaying actual thickness.
|
|
Echo to echo scan
|
Measures the metal thickness only (ignore paint and coatings) greater than .080" or 2 mm
|
|
Non-coded B-Scan
|
Displays a cross section of the test piece
|
|
Alpha-numeric datalogger
|
Saves 50,000 (expandable to optional 100,000) thickness readings with identification tag, date, time stamp
|
|
RF; Full Wave, Half +, Half - rectification modes
|
Hassel free operation
|
|
Auto Zoom to center echoes in middle of screen
|
No need to adjust range
|
|
Manul and Auto Gain
|
Ideal for complete waveform adjustment and control
|
|
world’s smallest ultrasonic thickness gage with high resolution waveform display
|
5" (127 mm) (L) x 3" (76.2 mm) (W) x 1.25" (31.75 mm) (H)
|
|
Echo to echo scan
|
Measures the metal thickness only (ignores paint and coatings) greater than .080" or 2 mm
|
|
Non-coded B-Scan
|
To display a cross section of the test piece
|
|
Alpha-numeric datalogger
|
Can save 50,000 (expandable to optional 100,000) thickness readings with identification tag, date, time stamp
|
|
USB port complete with interface cable
|
Can connect to a PC.
|
|
Freeze mode
|
Freezes display
|
|
Hold mode
|
Holds display to retain last thickness reading
|
|
Standard EHC-09 includes
|
Ultrasonic thickness gage, DZ-537 potted, 5 MHz 0.375 inch diameter, operation manual, cable, couplant
|
|
Scan mode
|
Displays minimum or maximum thickness value at 20 measurements per second (ideal for high temperature thickness reading and tracking the minimum depth alarm). Press Freeze to capture last valid minimum thickness readings prior to Loss of Signal (LOS), without reading the couplant upon lifting probe off test piece
|
|
Shut off
|
Auto, time out (after X minutes user programmable after no reading, loss or no key press)
|
|
Ergonomics
|
User selectable lefty or rightly display changes via keypad
|
|
Automatic probe wear indicator (Transducer attendant
|
Automatically informs the operator to replace the transducer
|
|
Package
|
Custom, splash-proof, high impact plastic with rubber, illuminating keypad for go/no-go testing
|
|
|
|